HIKmicro AD22P acoustic water leak detector
Water leaking from pressurized pipes can escape through small openings and cracks, generating sound and causing micro-vibrations in the pipe/liquid column. The HIKmicro AD22P acoustic water leak detector detects the noises/micro-vibrations, processes them, and displays the presumed proximity and intensity of the water leak.
Based on the instrument's display, the location of the leak can be identified. The instrument also transforms the sounds/micro-vibrations into the audible frequency range. The intensity of the audible noise increases as we get closer to the leak.
The uniqueness of the instrument is that it is equipped with sensors suitable for both indoor and outdoor measurements. Its applicability is therefore not limited to detecting leaks within buildings.
HIKmicro AD22P acoustic water leak detector - features
- Leak detection through audible noise and ultrasound detection
- Graphical display of the noise source (location of the leak) and its severity
- Applicable to any pressurized liquid pipes/fittings
- Recommended for checking pipes, connections, joints, couplings, distributors, etc.
- Suitable for both outdoor and indoor measurements
- SuperDetect procedure for quick identification of leak locations
- Four selectable digital bandpass filters
- Indoor frequency range 5 kHz ... 16 kHz or 8 kHz ... 16 kHz
- Outdoor frequency range 200 Hz ... 2 kHz
- Freely adjustable frequency range 200 Hz ... 16 kHz
- 1024 × 600 resolution, 7" LCD touchscreen
- Up to 11 hours of continuous operation on battery
- Storage in 4GB internal memory (approximately 60,000 images, approximately 10 hours of audio recording)
- Two types of sensors (indoor/outdoor), headphones, earphones, USB output
HIKmicro AD22P acoustic water leak detector - application areas:
Detection of outdoor and indoor leaks, and tightness issues
- Detection of leaks in industrial and drinking water pipe networks
- Components and seals of boilers, heat exchangers, and other pressurized equipment
- Verification of the closure of gate valves, fire hydrants, and other fittings
HIKmicro AD22P acoustic water leak detector - technical specifications:
Acoustic properties:
- Full frequency range 200 Hz ... 16 kHz
- Band filters
Indoor mid-frequency 5000 Hz - 16000 Hz
Indoor high-frequency 8000 Hz - 16000 Hz
Outdoor low-frequency 200 Hz - 2000 Hz
- Filter and gain: adjustable
- SuperDetect procedure: yes (indoor)
Image display:
- Display: 1024 × 600 pixels, 7" LCD touchscreen
- Screen brightness: manual / automatic adjustment
Data storage and communication:
- Storage: built-in EMMC (4 GB)
- Image storage capacity: approximately 60,000 images, viewable only on PC
- Audio storage capacity: approximately 10 hours, viewable only on PC
- Audio file format: .wav
- Image format: JPEG
- USB interface: USB 2.0, USB-C
General data:
- Operating temperature range between -10 °C and 50 °C
- Drop height: 1.2 m
- Instrument weight: 712 g
- Handheld sensor: 305 g
- Indoor sensor: 340 g
- Outdoor sensor: 318 g
- Headphones: 190 g (Headset)
- Earphones: 79 g, 158 g, 160 g
- Standard package: 3000 g
- Battery 3.6 V, rechargeable, lithium-ion
- Battery life: 11 hours, charging time: 4 hours
No further information available.