- Analog output: 0 ... 10 V, K hőelem, J hőelem, 0 ... 5 V
- Options/Configurations: RS485, RS232, Profibus DP, Ethernet, CAN, USB
- Design: külön elektronika-egység
- Measurement range (max.): 1600 °C
- Sensor temperature: -20 … 125 °C
- Electronics temperature: -20 … 85 °C
- Electronics dimension: 98 x 70 x 30 mm
- Temperature resolution: 0.1 K
- Measurement range (min.): 385 °C
- Time constant: 1 ms
- Alarm output: 24 V / 50 mA (open collector)
- Spectral Range - Wavelength: 1.6 µm
- Optics (ratio): 75:1
- Electrical supply: 5 ... 30 V DC
- Industrial protection: IP65
- Smallest measuring spot: SF: 7 mm közvetlen optika előtt, CF: 1,5 mm 110 mm távolságban
- Sensor size: M12 x 1 x 28 mm
- Measurement Accuracy: ±0,3 % ill, ±2,0 °C
- Explosion safety: -