Keresés

Menü

MSR 165 Multi-channel Measurement System

Home » Product Range » Special (miniature) data loggers » MSR 165 Multi-channel Measurement System

MSR 165 Multi-channel Measurement System

Data collector for shock and vibration

MSR_145
MSR_145



MSR 165 Multi-channel Measurement System

MSR 165 Multi-channel Measurement System: Data Logger for Impact and Vibration Measurement

The pinnacle of traffic monitoring, fault diagnostics, and load tests! The robust MSR 165 Multi-channel Measurement System can perform 1600 acceleration (shock and vibration) measurements per second on all 3 axes for up to 5 years. The shock observation range can be selected from ±15 g to ±200 g, and thanks to the PreTrigger feature, the 32 measurement data points before the event occurrence are also recorded.

MSR 165 Multi-channel Measurement System: More than a billion measured values

The built-in memory allows storage of 2 million measured values, enough for recording over 10,000 shock events. With a microSD card (≥4GB), this capacity can be expanded to 1 billion measured data points. The saved data can be easily and quickly accessed directly on a PC or laptop from the card, or via a USB connection.

MSR ShockViewer for Impact and Vibration Analysis

The delivery scope of MSR165 includes the MSR PC software for data configuration and analysis. With MSR165 Firmware Version 2.00 and newer versions, you have access to the MSR ShockViewer analysis software specifically tailored to the requirements of transportation monitoring, allowing extensive analysis and graphical representation of data recorded in shock mode, as well as automatic report generation.

MSR 165 Multi-channel Measurement System: Ideal for long-term measurements

The waterproof housing of MSR 165 data logger has extremely low power consumption, thanks to the minimal power usage of the high-performance 3-axis accelerometer. The rechargeable 900 mAh lithium-polymer battery enables monitoring of shocks for up to 6 months. For measurements lasting longer than this, the device can be equipped with long-life MSR Power Pack batteries, allowing the device to record up to 6 times more data.

Shock observation ranges of ±15 g and ±200 g are available, and thanks to the PreTrigger feature, the 32 measurement data points before the event occurrence are also recorded.

With a few clicks, you can select and request a non-binding quote for the desired MSR165.

1. Housing and Battery Selection.

Housing and Battery SelectionTechnical SpecificationsProduct Code
LiPo Battery (900 mAh),
Rechargeable via USB.

MSR165 data logger with rechargeable 900 mAh lithium-polymer battery.

Dimensions and Weight:
39 x 23 x 72 mm, approx. 69 g
Housing:Anodized aluminum casing, waterproof (IP67)
Color:Blue/anthracite
Medium:Air, other liquids
Push Button:Bookmark setting, start/stop function
 
Built-in Sensor:3-axis digital accelerometer (13-bit resolution), ±15 g or ±200 g.
 
Memory:Over 2 million measured values – expandable up to 1 billion values with microSD card
 
Connector:USB
PC Software:Free installation, Reader, Viewer, and Online software (Windows 7/8/10) for data recording and evaluation.
 
Operating Conditions:-20…+65 °C
Storage Conditions:
  • +5…+45 °C (ideal for battery storage)
  • 10…95 % relative humidity, non-condensing environment
 
Certification:The MSR 165 complies with the EU RoHS / WEEE standard.

165B8

Error

Replaceable Li-SOCl2 Battery
(3.6 V, 2 x 7700 mAh)
drip-proof cast
aluminum housing

MSR165 data logger with two replaceable 7700 mAh Li-SOCl2 batteries in a splash-proof aluminum housing.

Dimensions and weight:
122 x 92 x 70 mm, approx. 530 g

165B52

Error

2. Optional sensors.

If you would like to have the 200g 3-axis accelerometer instead of the 15g sensor in the MSR 165 Multi-channel data logger, as well as other sensors, select them here:

Measured parameter /
Measurement/storage time
Operating range /
Accuracy
Internal
sensor
External sensor (by cable length)
0.20 m1.00 m1.60 m
Temperature

1/s – 12 h

external: -55…+125 °C
internal: -20…+65 °C

±0.5 °C (-10…+65 °C)
±2 °C (-55…+125 °C)
Item No. T2
Error
Item No. FT2/020
Error
Item No. FT2/100
Error
Item No. FT2/160
Error
Relative humidity
(with built-in temperature sensor)

1/s – 12 h

0…100 % rel. hum.
external: -20…+85 °C
internal: -20…+65 °C

±2 % rel. hum.
(10…85 %, 0…+40 °C)
±4 % rel. hum.
(85…95 %, 0…+40 °C)
Item No. H3
Error
Item No. FH2/020
Error
Item No. FH2/100
Error
Device No. FH2/160
Error
Air Pressure
(absolute, with built-in
temperature sensing)

1/s – 12 h

0…2000 mbar absolute
external: -20…+85 °C
internal: -20…+65 °C

±2.5 mbar
(750…1100 mbar absolute,
+25 °C)
Device No. P5
Error
Device No. FP10/020
Error
Device No. FP10/100
Error
Device No. FP10/160
Error
0…14 bar absolute
-20…+65 °C

±50 mbar
(1…10 bar abs., +25 °C)
Device No. P7
Error
Device No. FP7/020
Error
Device No. FP7/100
Error
Device No. FP7/160
Error
3-axis Accelerometer

1600/s – 12 h
(±15 %)

±15 g
-20…+65 °C

±0.15 g (0…5 g, +25 °C)
±0.3 g (5…15 g, +25 °C)
Device No. A
Error
Device No. FA/020
Error
Device No. FA/100
Error
Item No. FA/160
Error
±200 g
-20…+65 °C

±2 g (0…15 g, +25 °C)
±5 g (15…100 g, +25 °C)
±10 g (100…200 g, +25 °C)
Item No. A3
Error
Item No. FA3/020
Error
Item No. FA3/100
Error
Item No. FA3/160
Error
Light

1/s – 12 h

0…65 000 lx
max. sensitivity
500 nm
Item No. L2
Error
Item No. FL2/020
Error
Item No. FL2/100
Error
Item No. FL2/160
Error

3. Do you need 4 additional inputs to connect sensors from a third party?

Do you need 4 additional inputs to connect sensors from a third party?

Analog inputInputInput configurationProduct code
Screw terminal for 4 analogue inputs.

Includes alarm output
and input for starting and stopping
data recording

Measurement/storage speed:
1/s to 12 h (or 1000/s if
the acceleration speed is
lower than 1/s)
Max. 2 external sensor connections,
light sensor not available.

4 analog Inputs
(Resolution: 12 bit)
0…3.0 V – Standard E3333
Error
4 Analog Inputs
(Resolution: 12 bit)
Select the number of inputs for the
appropriate configuration:

(1)   0…20 mA
(2)   4…20 mA
(3)   0…3.0 V
(4)   0.5…4.5 V / 0…5.0 V
(5)   0…10.0 V / 1.0…6.0 V
(6)   0…12.0 V
(7)   0…24.0 V
(8)   0…36.0 V
(9)   0…48.0 V

Exxxx
Error

4. Would you like to expand the capacity of the MSR165 with a microSD card?

Please order the connector for the standard microSD card here.Product Code
As needed, the MSR165 is equipped with a housing suitable for a microSD card (one ≥4GB card included). With the card, the number of measurement data of the MSR 165 can be expanded to over one billion. This is interchangeable even during operation.
Please note that expanding with a microSD card only complies with the IP60 standard.
N10006