No further information available.
Home » Product Range » Special (miniature) data loggers » MSR 165 Multi-channel Measurement System
Data collector for shock and vibration
The pinnacle of traffic monitoring, fault diagnostics, and load tests! The robust MSR 165 Multi-channel Measurement System can perform 1600 acceleration (shock and vibration) measurements per second on all 3 axes for up to 5 years. The shock observation range can be selected from ±15 g to ±200 g, and thanks to the PreTrigger feature, the 32 measurement data points before the event occurrence are also recorded.
The built-in memory allows storage of 2 million measured values, enough for recording over 10,000 shock events. With a microSD card (≥4GB), this capacity can be expanded to 1 billion measured data points. The saved data can be easily and quickly accessed directly on a PC or laptop from the card, or via a USB connection.
The delivery scope of MSR165 includes the MSR PC software for data configuration and analysis. With MSR165 Firmware Version 2.00 and newer versions, you have access to the MSR ShockViewer analysis software specifically tailored to the requirements of transportation monitoring, allowing extensive analysis and graphical representation of data recorded in shock mode, as well as automatic report generation.
The waterproof housing of MSR 165 data logger has extremely low power consumption, thanks to the minimal power usage of the high-performance 3-axis accelerometer. The rechargeable 900 mAh lithium-polymer battery enables monitoring of shocks for up to 6 months. For measurements lasting longer than this, the device can be equipped with long-life MSR Power Pack batteries, allowing the device to record up to 6 times more data.
Shock observation ranges of ±15 g and ±200 g are available, and thanks to the PreTrigger feature, the 32 measurement data points before the event occurrence are also recorded.
With a few clicks, you can select and request a non-binding quote for the desired MSR165.
| Housing and Battery Selection | Technical Specifications | Product Code | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LiPo Battery (900 mAh), Rechargeable via USB. ![]() Dimensions and Weight: 39 x 23 x 72 mm, approx. 69 g |
| 165B8 Error | ||||||||||||||||||||||||||||||||
| Replaceable Li-SOCl2 Battery (3.6 V, 2 x 7700 mAh) drip-proof cast aluminum housing ![]() Dimensions and weight: 122 x 92 x 70 mm, approx. 530 g | 165B52 Error |
If you would like to have the 200g 3-axis accelerometer instead of the 15g sensor in the MSR 165 Multi-channel data logger, as well as other sensors, select them here:
| Measured parameter / Measurement/storage time | Operating range / Accuracy | Internal sensor | External sensor (by cable length) | ||
|---|---|---|---|---|---|
| 0.20 m | 1.00 m | 1.60 m | |||
| Temperature 1/s – 12 h | external: -55…+125 °C internal: -20…+65 °C ±0.5 °C (-10…+65 °C) ±2 °C (-55…+125 °C) | Item No. T2 Error | Item No. FT2/020 Error | Item No. FT2/100 Error | Item No. FT2/160 Error |
| Relative humidity (with built-in temperature sensor) 1/s – 12 h | 0…100 % rel. hum. external: -20…+85 °C internal: -20…+65 °C ±2 % rel. hum. (10…85 %, 0…+40 °C) ±4 % rel. hum. (85…95 %, 0…+40 °C) | Item No. H3 Error | Item No. FH2/020 Error | Item No. FH2/100 Error | Device No. FH2/160 Error |
| Air Pressure (absolute, with built-in temperature sensing) 1/s – 12 h | 0…2000 mbar absolute external: -20…+85 °C internal: -20…+65 °C ±2.5 mbar (750…1100 mbar absolute, +25 °C) | Device No. P5 Error | Device No. FP10/020 Error | Device No. FP10/100 Error | Device No. FP10/160 Error |
| 0…14 bar absolute -20…+65 °C ±50 mbar (1…10 bar abs., +25 °C) | Device No. P7 Error | Device No. FP7/020 Error | Device No. FP7/100 Error | Device No. FP7/160 Error | |
| 3-axis Accelerometer 1600/s – 12 h | ±15 g -20…+65 °C ±0.15 g (0…5 g, +25 °C) ±0.3 g (5…15 g, +25 °C) | Device No. A Error | Device No. FA/020 Error | Device No. FA/100 Error | Item No. FA/160 Error |
| ±200 g -20…+65 °C ±2 g (0…15 g, +25 °C) ±5 g (15…100 g, +25 °C) ±10 g (100…200 g, +25 °C) | Item No. A3 Error | Item No. FA3/020 Error | Item No. FA3/100 Error | Item No. FA3/160 Error | |
| Light 1/s – 12 h | 0…65 000 lx max. sensitivity 500 nm | Item No. L2 Error | Item No. FL2/020 Error | Item No. FL2/100 Error | Item No. FL2/160 Error |
Do you need 4 additional inputs to connect sensors from a third party?
| Analog input | Input | Input configuration | Product code |
|---|---|---|---|
![]() Includes alarm output Measurement/storage speed: | 4 analog Inputs (Resolution: 12 bit) | 0…3.0 V – Standard | E3333 Error |
| 4 Analog Inputs (Resolution: 12 bit) | Select the number of inputs for the appropriate configuration: (1) 0…20 mA | Exxxx Error |
| Please order the connector for the standard microSD card here. | Product Code |
|---|---|
| As needed, the MSR165 is equipped with a housing suitable for a microSD card (one ≥4GB card included). With the card, the number of measurement data of the MSR 165 can be expanded to over one billion. This is interchangeable even during operation. Please note that expanding with a microSD card only complies with the IP60 standard. | N10006 Error |